WBox type terminals serve for scanning of contactless cards with its immediate recording to internal memory, backed up by an accumulator. From the operational view, they can be autonomous or operating ON LINE, with possibility to transfer to OFF LINE mode, when communication problems occur. They are equipped with MCS-51 microcontroller. They are used in access control, attendance and catering systems - everytime working in different modes. The terminal guarantee is 24 months.
WBox_72K | |
Scanning range with inner antenna | from 5 cm – by the type of ID card |
Signalization | acoustic and optical |
Operation cover | IP 43 or IP 65 |
Voltage / current supply | 9-18V DC / up to 200mA |
Supply galvanically separated | yes |
Display | 2 x 16 symbols |
Membrane keyboard* | WBox_72K - 24 keys |
Inputs* | 4 opto (door opening and locking, cover removal, EZS activation ) |
Outputs* | 2 switching contacts (operating of an electric lock, gate, turnstile and step motor) |
Communication interface* | RS485, RS232, LAN TCP/IP |
Galvanic communication separation | yes |
Dimensions | 150 x 195 x 45 [mm] |
Weight | 350g |
Access rights | |
Allowed cards chart capacity | 5445 records (personal time zones), RAM 128 kB backed up by an accumulator |
Time zones | 31 time zones defined as set of 1-32 time intervals, days of validity according to the weekday or working calendar |
PIN code checking | always / with activated EZS / never |
Chart of passages | |
Chart of passages capacity | 6553 records with overfill control, RAM 128 kB backed up by an accumulator |
Passage time | year, month, day, hour, minute, second |
Interruption codes | 4 groups ( arrival or departure, arrival, departure, system reports), each can contain 16384 different interruption codes |
System reports* | EZS activation, cover removal, door locking, PIN input error, quiet alarm, passage without opening the door, unproper door closing, opening the door by the key,… |
Passage without giving the reason, automatic arrival/departure switching | choice of the processing way - save/not save the passage, open/close the door, set the passage code, 8 switching times (hour, minute) |
Special functions | |
ON-LINE terminal control from PC | door opening, unit passage blocking |
Automatic door opening | 8 time intervals of open doors (interval validity according to the weekday or calendar, hour and minute beginning and interval end) |